翻訳と辞書
Words near each other
・ Breaking Bad (season 1)
・ Breaking Bad (season 2)
・ Breaking Bad (season 3)
・ Breaking Bad (season 4)
・ Breaking Bad (season 5)
・ Breaking ball
・ Breaking Benjamin
・ Breaking Benjamin (EP)
・ Breaking Benjamin discography
・ Breaking Bonaduce
・ Breaking Boredom Project
・ Breaking bread
・ Breaking Bread (TV series)
・ Breaking bulk
・ Breaking bulk (law)
Breaking capacity
・ Breaking character
・ Breaking Circus
・ Breaking Curfew
・ Breaking Dad
・ Breaking Dawn
・ Breaking Dawn (2004 film)
・ Breaking Dawn (disambiguation)
・ Breaking Dawn soundtrack
・ Breaking Daylight
・ Breaking Down the Bars
・ Breaking down the script
・ Breaking Free
・ Breaking Free (disambiguation)
・ Breaking Glass


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Breaking capacity : ウィキペディア英語版
Breaking capacity

Breaking capacity or interrupting rating is the current that a fuse, circuit breaker, or other electrical apparatus is able to interrupt without being destroyed or causing an electric arc with unacceptable duration. The prospective short circuit current which can occur under short circuit conditions should not exceed the rated breaking capacity of the apparatus. Otherwise breaking of the current cannot be guaranteed. Breaking capacity current corresponds to a voltage, so an electrical apparatus may have more than one breaking capacity current, according to the voltage. Breaking current may be stated in terms of the total current or just in terms of the alternating-current (symmetrical) component. Since the time of opening of a fuse or switch is not coordinated with the reversal of the alternating current, in some circuits the total current may be offset and can be larger than the alternating-current component by itself.〔Donald G. Fink and H. Wayne Beaty, ''Standard Handbook for Electrical Engineers, Eleventh Edition'',McGraw-Hill, New York, 1978, ISBN 0-07-020974-X, page 10-64〕
==Choosing breaking capacity==
Calculation of the required breaking capacity involves determining the supply impedance and voltage. Supply impedance is calculated from the impedance of the elements making up the supply system. Customers of an electrical supply utility can request the maximum value of prospective short circuit current available at their point of supply. Networks involving multiple sources of current, such as multiple generators, electric motors, and with variable interconnections may be analyzed with a computer. A system study will generally consider the maximum case of additions of generation and interconnection out to some projected horizon year, to allow for system growth during the useful life of the studied installation. Since practical calculations involve a number of approximations and estimates, some judgment is required in applying the results of a short-circuit calculation to the selection of apparatus.〔IEEE Standard 141-1993, page 113〕

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Breaking capacity」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.